FPR-C9300-DC - Cisco Firepower 9300 Series Appliances

Mfr. Part #: FPR-C9300-DC
Brand: Cisco
Condition: New
  • Warranty: 90-day return/replacement

    Click here to read our Return Policy for returns/replacements.

  • Authenticity: Original Genuine OEM

FPR-C9300-DC

FPR-C9300-DC - Cisco Firepower 9300 Series Appliances
Free ground shipping within the
United States
Sam Gov

Government, Federal & Education Procurement

We support quotes, POs, stock docs, and compliance invoicing.

Email: support@buyrouterswitch.com SAM.gov Registered Vendor CAGE Code : 23P86
overview
specifications
faqs
reviews

FPR-C9300-DC Overview

Firepower 9300 Chassis for DC Power Supply. 2 PSU/4 fans FPR-C9300-DC

Overview

This carrier-grade next-generation firewall (NGFW) is ideal for data centers and other high-performance settings that require low latency and high throughput. Deliver scalable, consistent security to workloads and data flows across physical, virtual, and cloud environments. With tightly integrated services, the Firepower 9000 Series lowers costs and supports open, programmable networks.  

Quick Specs

Figure 1 shows the appearance of FPR-C9300-DC.

 FPR-C9300-DC

Product Number

FPR-C9300-DC

Dimensions (H x W x D)

5.25 x 17.5 x 32 in. (13.3 x 44.5 x 81.3 cm)

Form factor

3 Rack Units (3RU), fits standard 19-in. (48.3-cm) square-hole rack

Security module slots

3

Network module slots

2 (within supervisor)

Supervisor

Cisco Firepower 9000 Supervisor with 8 x 10 Gigabit Ethernet ports and 2 network module slots for I/O expansion

Security modules

●  Cisco Firepower 9000 Security Module 24 with 2 x SSDs in RAID-1 configuration

●  Cisco Firepower 9000 Security Module 36 with 2 x SSDs in RAID-1 configuration

Network modules

●  8 x 10 Gigabit Ethernet Enhanced Small Form-Factor Pluggable (SFP+) network modules

●  4 x 40 Gigabit Ethernet Quad SFP+ network modules

●  2 x 100 Gigabit Ethernet Quad SFP28 network modules (double-wide, occupies both network module bays)

Note: Firepower 9300 may also be deployed as a dedicated threat sensor, with fail-to-wire network modules. Please contact your Cisco representative for details.

Maximum number of interfaces

Up to 24 x 10 Gigabit Ethernet (SFP+) interfaces; up to 8 x 40 Gigabit Ethernet (QSFP+) interfaces with 2 network modules

Integrated network management ports

1 x Gigabit Ethernet copper port (on supervisor)

Serial port

1 x RJ-45 console

USB

1 x USB 2.0

Storage

Up to 2.4 TB per chassis (800 GB per security module in RAID-1 configuration)

Power supplies

AC power supply

-48V DC power supply

HVDC power supply

Input voltage

200 to 240V AC

-40V to -60V DC*

240 to 380V DC

Maximum input current

15.5A to 12.9A

69A to 42A

<14A at 200V

Maximum output power

2500W

2500W

2500W

Frequency

50 to 60 Hz

-

-

Efficiency (at 50% load)

92%

92%

92% (at 50% load)

Redundancy

1+1

Fans

4 hot-swappable fans

Noise

75.5 dBA at maximum fan speed

Rack mountable

Yes, mount rails included (4-post EIA-310-D rack)

Weight

105 lb (47.7 kg) with one security module; 135 lb (61.2 kg) fully configured

Temperature: standard operating

Up to 10,000 ft (3000 M): 32 to 104°F (0 to 40°C) for SM-24 module

32 to 88°F (0 to 35°C) for SM-36 module at sea-level

Altitude adjustment notes:

For SM-36, maximum temp is 35⁰C, for every 1000 feet above sea level subtract 1⁰C

Temperature: NEBS operating

Long term: 0 to 45°C, up to 6,000 ft (1829 m)

Long term: 0 to 35°C, 6,000 to 13,000 ft (1829-3964 m)

Short term: -5 to 55°C, up to 6,000 ft (1829 m)

Note: CiscoFirepower 9300 NEBS compliance applies only to SM-24 configurations.

Temperature: nonoperating

-40 to 149°F (-40 to 65°C); maximum altitude is 40,000 ft

Humidity: operating

5 to 95% noncondensing

Humidity: nonoperating

5 to 95% noncondensing

Altitude: operating

SM-24: 0 to 13,000 ft (3962 m)

SM-36: 0 to 10,000 ft (3048 m); please see above Operating Temperature section for temperature adjustment notes

Altitude: nonoperating

40,000 ft (12,192 m)

* Minimum turn-on voltage is -44V DC

Need help with FPR-C9300-DC?

Get pricing, availability, lead time, and compatible options from our team. Chat with us live or email support@buyrouterswitch.com

Specification

FPR-C9300-DC Specification

FPR-C9300-DC Specification

Dimensions (H x W x D)

5.25 x 17.5 x 32 in. (13.3 x 44.5 x 81.3 cm)

Form factor

3 Rack Units (3RU), fits standard 19-in. (48.3-cm) square-hole rack

Security module slots

3

Network module slots

2 (within supervisor)

Supervisor

Cisco Firepower 9000 Supervisor with 8 x 10 Gigabit Ethernet ports and 2 network module slots for I/O expansion

Security modules

●  Cisco Firepower 9000 Security Module 24 with 2 x SSDs in RAID-1 configuration

●  Cisco Firepower 9000 Security Module 36 with 2 x SSDs in RAID-1 configuration

Network modules

●  8 x 10 Gigabit Ethernet Enhanced Small Form-Factor Pluggable (SFP+) network modules

●  4 x 40 Gigabit Ethernet Quad SFP+ network modules

●  2 x 100 Gigabit Ethernet Quad SFP28 network modules (double-wide, occupies both network module bays)

Note: Firepower 9300 may also be deployed as a dedicated threat sensor, with fail-to-wire network modules. Please contact your Cisco representative for details.

Maximum number of interfaces

Up to 24 x 10 Gigabit Ethernet (SFP+) interfaces; up to 8 x 40 Gigabit Ethernet (QSFP+) interfaces with 2 network modules

Integrated network management ports

1 x Gigabit Ethernet copper port (on supervisor)

Serial port

1 x RJ-45 console

USB

1 x USB 2.0

Storage

Up to 2.4 TB per chassis (800 GB per security module in RAID-1 configuration)

Power supplies

 

AC power supply

-48V DC power supply

HVDC power supply

Input voltage

200 to 240V AC

-40V to -60V DC*

240 to 380V DC

Maximum input current

15.5A to 12.9A

69A to 42A

<14A at 200V

Maximum output power

2500W

2500W

2500W

Frequency

50 to 60 Hz

-

-

Efficiency (at 50% load)

92%

92%

92% (at 50% load)

Redundancy

1+1

Fans

4 hot-swappable fans

Noise

75.5 dBA at maximum fan speed

Rack mountable

Yes, mount rails included (4-post EIA-310-D rack)

Weight

105 lb (47.7 kg) with one security module; 135 lb (61.2 kg) fully configured

Temperature: standard operating

Up to 10,000 ft (3000 M): 32 to 104°F (0 to 40°C) for SM-24 module

32 to 88°F (0 to 35°C) for SM-36 module at sea-level

Altitude adjustment notes:

For SM-36, maximum temp is 35⁰C, for every 1000 feet above sea level subtract 1⁰C

Temperature: NEBS operating

Long term: 0 to 45°C, up to 6,000 ft (1829 m)

Long term: 0 to 35°C, 6,000 to 13,000 ft (1829-3964 m)

Short term: -5 to 55°C, up to 6,000 ft (1829 m)

Note: Cisco Firepower 9300 NEBS compliance applies only to SM-24 configurations.

Temperature: nonoperating

-40 to 149°F (-40 to 65°C); maximum altitude is 40,000 ft

Humidity: operating

5 to 95% noncondensing

Humidity: nonoperating

5 to 95% noncondensing

Altitude: operating

SM-24: 0 to 13,000 ft (3962 m)

SM-36: 0 to 10,000 ft (3048 m); please see above Operating Temperature section for temperature adjustment notes

Altitude: nonoperating

40,000 ft (12,192 m)

* Minimum turn-on voltage is -44V DC

Frequently Asked Questions

What is the primary function of the Cisco FPR-C9300-DC chassis? +
The Cisco FPR-C9300-DC serves as the foundational hardware chassis for the Firepower 9300 security appliance series. It is specifically engineered to provide the structural framework, power distribution, and thermal management required to host high-performance security modules in data center environments relying on direct current (DC) power infrastructure.
Does the FPR-C9300-DC include pre-installed cooling components? +
Yes, this chassis configuration comes standard with a set of four integrated fans. These fans are essential for maintaining the optimal thermal envelope for high-density security modules, ensuring consistent airflow and preventing potential overheating during heavy traffic loads or intensive cryptographic processing tasks within your data center rack.
How many power supply units are supported by the FPR-C9300-DC? +
The FPR-C9300-DC is designed to accommodate two power supply units. This dual-PSU capability is critical for environments that require power redundancy. By utilizing both bays, you can ensure high availability for your security services, mitigating the risk of downtime in the event of a single power feed failure.
Is the FPR-C9300-DC compatible with standard enterprise server racks? +
The chassis is built to standard rack-mount specifications, making it fully compatible with most professional-grade network cabinets and data center racks. When deploying this unit, ensure your rack has sufficient depth and support to accommodate the physical dimensions and weight of the Firepower 9300 series hardware.
What is the significance of the DC designation in this Cisco model? +
The 'DC' designation confirms that this specific unit is configured for direct current power inputs. This is a critical requirement for telecommunications facilities and data centers that utilize DC power plants to improve energy efficiency and provide a direct interface with battery backup systems, rather than relying on standard AC power.
Can the FPR-C9300-DC support multiple security modules simultaneously? +
The chassis is engineered for a modular architecture, allowing you to scale your security deployment by inserting various security modules into the available slots. This allows administrators to consolidate multiple security functions—such as firewalling, IPS, and malware protection—into a single physical appliance for streamlined management.
How should I plan for the power load of the FPR-C9300-DC? +
When provisioning power, account for the maximum draw of the fully populated chassis. Because this unit utilizes DC power, ensure your distribution panels are rated for the required voltage and amperage. Proper electrical planning is vital to ensure that your security infrastructure remains operational during peak throughput and hardware utilization.
Are there specific maintenance requirements for the FPR-C9300-DC fans? +
To maintain optimal reliability, inspect the intake and exhaust vents regularly to ensure no obstructions restrict airflow. While the integrated fans are designed for long-term data center operation, monitoring the environmental status via the Firepower management interface allows you to proactively identify potential thermal irregularities before they impact the security modules.
How can I obtain a bulk quote for the FPR-C9300-DC chassis? +
For organizations planning large-scale security deployments or needing multiple chassis for regional data center upgrades, our team at BuyRouterSwitch.com is ready to assist. Please contact our sales department directly to discuss volume pricing, current inventory availability, and tailored procurement options to meet your project requirements and budgetary constraints.
Why should I choose BuyRouterSwitch.com for my Cisco infrastructure needs? +
BuyRouterSwitch.com specializes in providing authentic enterprise networking equipment to IT professionals globally. We prioritize a secure ordering process and efficient procurement workflows, ensuring that your critical hardware arrives exactly as specified. By partnering with us, you gain access to a reliable supply chain dedicated to supporting your complex networking and security infrastructure needs.

Need Help Choosing the Right Part? Talk to an Expert

  • +1 (800) 870-9487
    Mon-Fri 8am-5pm EST
  • support@buyrouterswitch.com
    Technical support
People