C9410R - Cisco Switch Catalyst 9400

Mfr. Part #: C9410R
Brand: Cisco
Condition: Refurbished
  • Warranty: 90-day return/replacement

    Click here to read our Return Policy for returns/replacements.

C9410R

C9410R - Cisco Switch Catalyst 9400
Free ground shipping within the
United States

Government, Federal & Education Procurement

We support quotes, POs, stock docs, and compliance invoicing.

Email: support@buyrouterswitch.com SAM.GOV CAGE Code : 23P86
overview
specifications
faqs
reviews

C9410R Overview

Cisco Catalyst 9400 Series 10 slot chassis, need to be ordered with configured accessories C9410R

Overview
C9410R Overview

Cisco C9410R

Cisco Catalyst 9400 Series 10 slot chassis. The Cisco Catalyst® 9400 Series switches are Cisco’s leading modular enterprise switching access platform built for security, IoT and cloud. The platform provides unparalleled investment protection with a chassis architecture that is capable of supporting up to 9Tbps of system bandwidth and unmatched power delivery for high density IEEE 802.3BT (60W PoE).

Quick Specs

Figure 1 shows the appearance of C9410R.

 C9410R

Feature

Cisco Catalyst C9410R

Total number of slots

10

Line-card slots

8

Supervisor engine slots

2

Dedicated supervisor engine slot numbers

5 and 6

Supervisor engine redundancy

Yes

Supervisor engines supported

C9400-SUP-1,

C9400-SUP-1XL, C9400-SUP-1XL-Y

Maximum PoE per slot

2880W

Maximum Bandwidth scalability per line-card slot

Up to 480 Gbps on all slots

Number of power supply bays

8

AC input power

Yes

Integrated PoE

Yes

Power supplies supported

3200W AC, 2100W AC

Number of fan-tray bays

1

Location of 19-inch rack-mount

Front

Dimensions (H x W x D)

22.61 x 17.30 x 16.30 in. (57.43 x 43.97 x 31.70cm)

Rack Units (RU)

13 RU

Chassis weight (with fan tray)

65.0 lb (29.48 kg)

Mounting

19-in. rack compatible (19-in. rack and cable guide hardware included)

Regulatory compliance

22.61 x 17.30 x 16.30 in. (57.43 x 43.97 x 31.70cm)

Safety

●  UL 60950-1

●  CAN/CSA-C222.2 No. 60950-1

●  EN 60950-1

●  IEC 60950-1

●  AS/NZS 60950.1

●  IEEE 802.3

EMC

●  47 CFR Part 15

●  CISPR22 Class A

●  KN 32 Class A

●  EN 300 386 V1.6.1

●  EN 55022 Class A

●  EN 55032 Class A

●  CISPR 32 Class A

●  EN61000-3-2

●  EN61000-3-3

●  ICES-003 Class A

●  TCVN 7189 Class A

●  V-3 Class A

●  CNS13438 Class A

●  CISPR24

●  EN 300 386

●  EN55024

●  TCVN 7317

●  KN35

Industry EMC, safety, and environmental standards

●  NEBS: Operating temperature: -5 to 55C

●  Relative Humidity: 10-93%

●  Operating Altitude: up to 1829 m (6000 ft) at 55C

●  ETSI 300-019 Requirements are covered under GR-63-CORE with some deviations.

●  SR-3580 NEBS level 3 (GR-63-CORE, to current issue, GR-1089-CORE, to current issue)

●  ETS 300 019-2-1, Class 1.2 Storage

●  ETS 300 019-2-2, Class 2.3 Transportation

●  ETS 300 019-2-3, Class 3.2 Stationary

●  EN50121-4

●  EN 300 386

ROHS compliance

ROHS5

TheModules, Cards

C9410R.

Model

Description

Modules

C9400-SUP-1=

Cisco Catalyst 9400 Series Supervisor 1 Module

C9400-SUP-1XL-Y

Cisco Catalyst 9400 Series Supervisor 1XL-Y with 25G Module

C9400-SUP-1XL-Y/2

Cisco Catalyst 9400 Series Redundant Supervisor 1XL-Y with 25G Module

Power Supply 

C9400-PWR-3200AC

Cisco Catalyst 9400 Series 3200W AC Power Supply

C9400-PWR-2100AC

Cisco/Cisco Switches/Cisco Switch Catalyst 9400/Cisco Switch Catalyst 9400 Accessories

Compare to Similar Items

Feature

Cisco Catalyst C9404R

Cisco Catalyst C9407R

Cisco Catalyst C9410R

Total number of slots

4

7

10

Line-card slots

2

5

8

Supervisor engine slots

2

2

2

Dedicated supervisor engine slot numbers

2 and 3

3 and 4

5 and 6

Supervisor engine redundancy

Yes

Yes

Yes

Supervisor engines supported

C9400-SUP-1,

C9400-SUP-1XL, C9400-SUP-1XL-Y

C9400-SUP-1,

C9400-SUP-1XL, C9400-SUP-1XL-Y

C9400-SUP-1,

C9400-SUP-1XL, C9400-SUP-1XL-Y

Maximum PoE per slot

2880W

2880W

2880W

Maximum Bandwidth scalability per line-card slot

Up to 480 Gbps on all slots

Up to 480 Gbps on all slots

Up to 480 Gbps on all slots

Number of power supply bays

4

8

8

AC input power

Yes

Yes

Yes

Integrated PoE

Yes

Yes

Yes

Power supplies supported

3200W AC, 2100W AC

3200W AC, 2100W AC

3200W AC, 2100W AC

Cisco Catalyst 9400 Series 10 slot chassis

  • Rack mounting 13U
  • Cooling type: Active
  • 439.4 x 414 x 574.3 mm
  • Black, Grey

Summary Description

Cisco C9410R

Need help with C9410R?

Get pricing, availability, lead time, and compatible options from our team. Chat with us live or email support@buyrouterswitch.com

Specification

C9410R Specification

Cisco Catalyst C9410R Specification

Total number of slots

10

Line-card slots

8

Supervisor engine slots

2

Dedicated supervisor engine slot numbers

5 and 6

Supervisor engine redundancy

Yes

Supervisor engines supported

C9400-SUP-1,

C9400-SUP-1XL, C9400-SUP-1XL-Y

Maximum PoE per slot

2880W

Maximum Bandwidth scalability per line-card slot

Up to 480 Gbps on all slots

Number of power supply bays

8

AC input power

Yes

Integrated PoE

Yes

Power supplies supported

3200W AC, 2100W AC

Number of fan-tray bays

1

Location of 19-inch rack-mount

Front

Dimensions (H x W x D)

22.61 x 17.30 x 16.30 in. (57.43 x 43.97 x 31.70cm)

Rack Units (RU)

13 RU

Chassis weight (with fan tray)

65.0 lb (29.48 kg)

Mounting

19-in. rack compatible (19-in. rack and cable guide hardware included)

Regulatory compliance

22.61 x 17.30 x 16.30 in. (57.43 x 43.97 x 31.70cm)

Safety

●  UL 60950-1

●  CAN/CSA-C222.2 No. 60950-1

●  EN 60950-1

●  IEC 60950-1

●  AS/NZS 60950.1

●  IEEE 802.3

EMC

●  47 CFR Part 15

●  CISPR22 Class A

●  KN 32 Class A

●  EN 300 386 V1.6.1

●  EN 55022 Class A

●  EN 55032 Class A

●  CISPR 32 Class A

●  EN61000-3-2

●  EN61000-3-3

●  ICES-003 Class A

●  TCVN 7189 Class A

●  V-3 Class A

●  CNS13438 Class A

●  CISPR24

●  EN 300 386

●  EN55024

●  TCVN 7317

●  KN35

Industry EMC, safety, and environmental standards

●  NEBS: Operating temperature: -5 to 55C

●  Relative Humidity: 10-93%

●  Operating Altitude: up to 1829 m (6000 ft) at 55C

●  ETSI 300-019 Requirements are covered under GR-63-CORE with some deviations.

●  SR-3580 NEBS level 3 (GR-63-CORE, to current issue, GR-1089-CORE, to current issue)

●  ETS 300 019-2-1, Class 1.2 Storage

●  ETS 300 019-2-2, Class 2.3 Transportation

●  ETS 300 019-2-3, Class 3.2 Stationary

●  EN50121-4

●  EN 300 386

ROHS compliance

ROHS5

Frequently Asked Questions

What are the primary physical dimensions and slot capacity of the Cisco Catalyst C9410R chassis? +
The C9410R is a high-density, 10-slot modular chassis designed for the Cisco Catalyst 9400 Series. It features two slots dedicated for supervisor engines and eight slots specifically for line cards, providing a robust foundation for enterprise-grade switching. This modular architecture allows you to scale your campus network effectively while maintaining high port density within a standard rack footprint.
Does the C9410R chassis support redundant supervisor engines for high availability? +
Yes, the C9410R is engineered to support dual supervisor engines in the dedicated supervisor slots. This configuration enables stateful switchover (SSO) and non-stop forwarding (NSF), ensuring that your critical network operations remain uninterrupted during a supervisor failure. Implementing redundant supervisors is the industry-standard best practice for maintaining enterprise network resiliency.
Which types of line cards are compatible with the C9410R modular switch? +
The C9410R supports a wide range of Catalyst 9400 Series line cards, including high-density Cisco UPOE and UPOE+ models. These line cards are designed to provide scalable throughput and advanced power-over-ethernet capabilities for modern endpoints such as Wi-Fi 6 access points, IoT devices, and high-performance IP telephony, ensuring your infrastructure is ready for demanding edge requirements.
How should I configure the power supply requirements for the C9410R chassis? +
Power requirements for the C9410R are dependent on your specific line card configuration and total PoE budget. Because this is a modular chassis, you must calculate the aggregate draw of your supervisor modules, fan trays, and line cards. We recommend sizing your power supplies with N+1 or N+N redundancy to ensure consistent uptime and protection against power circuit failures.
What management features are available when using the C9410R in a campus environment? +
When paired with supported supervisors, the C9410R offers extensive management capabilities, including Cisco DNA Center integration, programmable APIs, and advanced telemetry. These tools allow network administrators to automate provisioning, monitor real-time traffic patterns, and enforce security policies consistently across the entire campus fabric from a centralized management interface.
Is the C9410R chassis suitable for software-defined access (SD-Access) deployments? +
Absolutely. The C9410R acts as a core, distribution, or access layer switch capable of serving as a fabric edge or border node in a Cisco SD-Access architecture. Its hardware-based virtualization features and deep packet inspection capabilities allow for segmenting user traffic, enforcing granular security, and simplifying network orchestration across your entire organizational footprint.
How do I ensure proper airflow and cooling for a fully populated C9410R chassis? +
The C9410R utilizes a front-to-back airflow design, which is standard for high-density enterprise modular switches. You must ensure that the rack environment has adequate ventilation and that the fan tray modules are functioning correctly. It is critical to maintain clear clearance at the front and back of the chassis to prevent thermal throttling and ensure the longevity of your installed hardware components.
Can I mix different generations of Catalyst 9400 line cards within the C9410R? +
The C9400 Series is designed for investment protection, typically allowing for the mixing of line cards across generations, provided that the supervisor engine firmware is updated to a compatible release. However, always verify that your specific supervisor version supports the feature sets and power requirements of the older or newer line cards you intend to mix within the 8 available line card slots.
Why should I choose BuyRouterSwitch.com for my Cisco C9410R procurement? +
BuyRouterSwitch.com specializes in providing authentic, enterprise-grade Cisco hardware at competitive price points. We focus on streamlining the complex configuration process for modular chassis, ensuring that your C9410R is paired with the correct accessories, power supplies, and modules required for your specific deployment, saving you time and preventing ordering errors common with modular network infrastructure.
How can I obtain a custom quote for a large-volume deployment of C9410R switches? +
For large-scale projects or complex network upgrades involving multiple C9410R chassis, our dedicated sales team provides comprehensive bulk quoting services. Contact our experts directly to discuss your project requirements, including power, line card densities, and chassis accessories. We facilitate efficient, secure ordering processes for enterprise clients looking to scale their infrastructure while ensuring all components are properly accounted for in your custom bill of materials.

Need Help Choosing the Right Part? Talk to an Expert

  • +1 (800) 870-9487
    Mon-Fri 8am-5pm EST
  • support@buyrouterswitch.com
    Technical support
People